logo

DINKONDA GLOBAL Power Plants Special 5-540m3/h, 0.7Mpa~600MPa Diesel Engine Multi-stage Centrifugal Pump Unit, Intelligent Emergency Diesel Engine Water Pump

DINKONDA GLOBAL Power Plants Special 5-540m3/h, 0.7Mpa~600MPa Diesel Engine Multi-stage Centrifugal Pump Unit, Intelligent Emergency Diesel Engine Water Pump
Basic Properties
country of origin
CHINA
Brand Name
DINKONDA
certificate
GB/T,ISO,CE
PRODUCT MODEL
TH Series
Trading Properties
MOQ
100PCS
unit price
$500-$1000
Packing
Export Standard Wooden Case/Pallet
period for dispatch
2-3 Weeks
payment method
T/T
Supply Capacity
10,000pcs/month

Product Details

Highlight:

Diesel Engine Centrifugal Pump Unit

,

Multi-stage Power Plant Pump

,

Emergency Diesel Water Pump 600MPa

Inletdiameter: 100-500 Mm
Protectionclass: IP67
Mounting: Base Mounted / Vertical Mounted
Feedback Type: Potentiometer, Limit Switch, Or Encoder
Operatingspeed: 10 To 120 Seconds Per 90°
Installationtype: Horizontal / Vertical
Duty Cycle: Continuous Or Intermittent
Drivetype: Direct Coupled / Belt Driven
Material: Stainless Steel / Cast Iron
Efficiency: Up To 85%
Temperaturerange: -20°C To 200°C
Maintenance: Low Maintenance With Easy Access Design
Motorpower: 100-500 KW
Manualoverride: Handwheel Or Lever
Pumptype: Centrifugal
Product Brief
DINKONDA GLOBAL Power Plants Special 5-540m3/h, 0.7Mpa~600MPa Diesel Engine Multi-stage Centrifugal Pump Unit, Intelligent Emergency Diesel Engine Water Pump Product OverviewDiesel multi-stage centrifugal pump unit, also known as intelligent emergency diesel engine water pump, is a mechanical and ...
Product Description

DINKONDA GLOBAL Power Plants Special 5-540m3/h, 0.7Mpa~600MPa Diesel Engine Multi-stage Centrifugal Pump Unit, Intelligent Emergency Diesel Engine Water Pump



Product Overview
Diesel multi-stage centrifugal pump unit, also known as intelligent emergency diesel engine water pump, is a mechanical and electrical integrated equipment designed by DINKONDA GLOBAL for emergency water supply or seawater desalination of industrial boilers in thermal power plants, chemical plants and other enterprises, which are far away from the power source. The diesel water pump can be selected from high-quality domestic or imported diesel engines according to different working conditions, matched with high-quality and efficient multi-stage centrifugal pumps. The diesel water pump is mainly used to pump clean water, and the temperature of the conveyed liquid shall not exceed 80 ℃. The flow range of the conveyed liquid is 5-540m3/h, the pressure range is 0.7Mpa~600MPa, the supporting power range is 22~900Kw, and the speed range is 980~2900rpm. Various types of pump heads can be selected according to the parameters and working conditions.




Scope Of Application

The multi-stage centrifugal pump diesel engine water pump unit driven by a diesel engine is suitable for mining, marine, seawater desalination, flood control and drainage, emergency drainage, factory and urban water supply and drainage. It is used to transport clean water without solid particles or liquids with physical and chemical properties similar to clean water. The temperature of the medium being transported is 0 ℃~80 ℃, and the allowable inlet pressure is 0.6MPa.




Characteristics And Advantages
1. Fully intelligent control - automatic inspection of multi-stage centrifugal pump units for diesel engines; Automatic program control; Automatic process control; Automatic data collection and display; Automatic fault diagnosis and relay protection.


2. Diesel engine multi-stage centrifugal pump unit fully digital direct control (DDC);  


3. Comprehensive information display of multi-stage centrifugal pump units for diesel engines.  


4. The operation status display of the multi-stage centrifugal pump unit of a diesel engine includes: standby, start-up, fuel supply, start-up, start-up delay, idle delay, normal operation, cooling shutdown, and emergency shutdown.


5. The operating parameters displayed for the multi-stage centrifugal pump unit of a diesel engine include: water pump speed, water pump head, cooling temperature, lubricating oil pressure, water pump flow rate, operating time, fuel inventory, starting battery voltage, and other parameters.


6. The protection settings for the multi-stage centrifugal pump unit of a diesel engine include: overspeed, low speed, low oil pressure, high cooling temperature, low temperature (below 4 ℃), low fuel level, low battery voltage, high battery voltage, uncalibrated speed signal, low water pressure and excessive flow rate of the water pump, etc; Automatic alarms such as no speed signal, overspeed, low speed, low oil pressure, high cooling temperature, startup failure, shutdown failure, open/short circuit of oil pressure sensor, open/short circuit of water temperature sensor, open/short circuit of speed sensor, low water pressure and overcurrent of water pump;  


7. The multi-stage centrifugal pump unit of the diesel engine adopts a domestically unique electromechanical integration design, and users only need to connect the inlet/outlet pipes and exhaust pipes to work;  


8. The multi-stage centrifugal pump unit of the diesel engine is equipped with a communication interface, which can be directly connected to the control center to achieve "four remote" (remote adjustment, remote communication, remote monitoring, remote control) monitoring and operation recording.

Ready To Send A Quick
Inquiry?

Have A Question? Fill Out The Form Below And We Will Get Back To You As Soon As Possible.

Please enter a valid email address.
Please Enter Your Inquiry Message.
Privacy Protected Quick Response Satisfaction Guaranteed